GV2MC IP55 Enclosure Box for GV2ME GV2MC IP55 Enclosure Box for GV2ME
  • Home
  • Products
    GV2MC IP55 Enclosure Box for GV2ME

    Automation & Control

    GV2MC IP55 Enclosure Box for GV2ME

    Circuit Breaker & Fuses

    GV2MC IP55 Enclosure Box for GV2ME

    Din-Rail Mounted Products

    GV2MC IP55 Enclosure Box for GV2ME

    Distribution Box & Cabinet

    GV2MC IP55 Enclosure Box for GV2ME

    Load Center & Meter Bases

    GV2MC IP55 Enclosure Box for GV2ME

    Solar PV Products

    GV2MC IP55 Enclosure Box for GV2ME

    Electrical Accessories

    GV2MC IP55 Enclosure Box for GV2ME

    Chint Electrical Materials

  • About
  • Blog
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
GV2MC IP55 Enclosure Box for GV2ME GV2MC IP55 Enclosure Box for GV2ME
Search
Sold out
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
Click to enlarge
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
GV2MC IP55 Enclosure Box for GV2ME
Home Automation & Control Motor Manual Starters GV2MC IP55 Enclosure Box for GV2ME
3TB AC Magnetic Contactor
3TB AC Magnetic Contactor
Back to products
Chint original 10x38 32A RT28-32 RT28N-32 RT28N-32X 14x51 63A RT28-63 RT28-63X 22x58 125A RT28-125 Chnt Fuse link and Holder
Chint original 10x38 32A RT28-32 RT28N-32 RT28N-32X 14x51 63A RT28-63 RT28-63X 22x58 125A RT28-125 Chnt Fuse link and Holder

GV2MC IP55 Enclosure Box for GV2ME

Rated Frequency:50/60hz
Type:Moulded Case
BCD Curve:C
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:GV2ME
Poles Number:3
Breaking Capacity:16kA
SKU: 1600076308855 Category: Motor Manual Starters
  • Description
  • Additional information
Description

GV2ME Enclosure IP55 GV2MC02 GV2MC03 IP41 GV2MC01 Enclosed Starter Motor Protection Circuit Breakers GV2ME with IP55 box

   

 

Application

GV2ME/GV3ME series motor protection circuit breaker (Motor Manual Starter) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.

 

Setting Range of
Thermal Trips
(A)
Maximum Horsepower Ratings GV2ME
Pushbutton
GV2P
Rotary Handle
Single Phase Three Phase
115V
(HP)
230V
(HP)
200V
(HP)
230V
(HP)
460V
(HP)
575V
(HP)
Catalog Number Catalog Number
0.11 – 0.16
0.016 – 0.25
0.25 – 0.40
0.40 – 0.63
0.63 – 1
1 – 1.6
1.6 – 2.5
2.5 – 4
4 – 6.3
6 – 10
9 – 14
13 – 18
17 – 23
20 – 25
24 – 32
–
–
–
–
–
–
–
1/8
1/4
1/2
3/4
1
1-1/2
2
2
–
–
–
–
–
1/10
1/6
1/3
1/2
1-1/2
2
3
3
3
5
–
–
–
–
–
–
1/2
3/4
1-1/2
2
3
5
5
5
10
–
–
–
–
–
–
1/2
1
1-1/2
3
3
5
7-1/2
7-1/2
10
–
–
–
–
1/2
3/4
1
2
3
5
10
10
15
15
20
–
–
–
–
1/2
1
1-1/2
3
5
7-1/2
10
15
20
20
30
GV2ME01
GV2ME02
GV2ME03
GV2ME04
GV2ME05
GV2ME06
GV2ME07
GV2ME08
GV2ME10
GV2ME14
GV2ME16
GV2ME20
GV2ME21
GV2ME22
GV2ME32
GV2P01
GV2P02
GV2P03
GV2P04
GV2P05
GV2P06
GV2P07
GV2P08
GV2P10
GV2P14
GV2P16
GV2P20
GV2P21
GV2P22
1 – 1.6
1.6 – 2.5
2.5 – 4
4 – 6
6 – 10
10 – 16
16 – 25
25 – 40
40 – 63
–
–
1/8
1/4
1/2
1
2
3
5
1/10
1/16
1/3
1/2
1-1/2
2
3
7-1/2
10
–
1/2
3/4
1-1/2
2
3
5
10
20
–
1/2
1
1-1/2
3
5
7-1/2
10
20
3/4
1
2
3
5
10
15
30
40
1
1-1/2
3
–
7-1/2
10
20
30
60
GV3ME06
GV3ME07
GV3ME08
GV3ME10
GV3ME14
GV3ME20
GV3ME25
GV3ME40
GV3ME63
 

 

Voltage Trips

– To order an undervoltage trip: replace the bullet (•) with a U (for example, GVAU025).
– To order a shunt trip: replace the bullet (•) with an S (for example, GVAS025).

Picture Only one trip or fault signaling contact can be installed per GV2ME/GV3ME device
Description Characteristics Voltage Frequency   

Catalog

Number        

Voltage trips
GV2 & GV3P
Undervoltage or
Shunt trip
(external mounting,
1 block right side only)
24 V 50 Hz
60 Hz
GVA•025
GVA•026
48 V 50 Hz
60 Hz
GVA•055
GVA•056
100–110 V 50/60 Hz GVA•107
110–115 V 50 Hz
60 Hz
GVA•115
GVA•116
120–127 V 50 Hz GVA•125
127 V 60 Hz GVA•115
200 V 50 Hz GVA•207
200–220 V 60 Hz GVA•207
220–240 V 50 Hz
60 Hz
GVA•225
GVA•226
380–400 V 50 Hz
60 Hz
GVA•385
GVA•386
415–440 V 50 Hz GVA•415
415 V 60 Hz GVA•416
440 V 60 Hz GVA•385
480 V 60 Hz GVA•415
500 V
600 V
50 Hz
60 Hz
GVA•505

 

Auxiliary Contact Blocks

Picture Description Mounting
Location
Max. No. of
Blocks
Contact Type Catalog Number
Instantaneous auxiliary contacts
GV2ME + GV3P
Frontbg 1 N.O. or N.C.
N.O. + N.C.
N.O. + N.O.
GVAE1
GVAE11
GVAE20
Left Hand Side 2 N.O. + N.C.
N.O. + N.O.
GVAN11
GVAN20
Fault signaling contact + instantaneous auxiliary contact GV2 + GV3P Left Hand Side 1 N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. GVAD1010
GVAD1001
GVAD0110
GVAD0101
Short circuit signaling contact
GV2 + GV3P
Left Hand Side 1 SPDT GVAM11

– Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
– Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
– The GVAD is always mounted next to the starter.
– For spring terminals, add 3 to the catalog number (for example, GVAE113).
– One trip or one fault signaling can be fitted per GV3.
– Cannot be used with GV2GH7 insulator.

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Rated Current

0.1A~32A

Rated Voltage

380V

Related products

Sold out
LC3-D TeSys Automatic Star Delta Motor Starter

LC3-D TeSys Automatic Star Delta Motor Starter

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC3-D
Phase:3
Main Circuit Rating Current:9A ~ 95A
LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter
LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter

LE1-D QCX2 IP65 Enclosed Magnetic Motor Starter

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:QCX2 (LE1-D)
Electricity Type:AC
Sold out
3VU Motor Protector Circuit Breaker

3VU Motor Protector Circuit Breaker

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:3VU1300 3VU1600
Breaking Capacity:20kA
Rated Voltage:380V
Type:Moulded Case
LE1D 3-Phase DOL Magnetic Motor Starter
LE1D 3-Phase DOL Magnetic Motor Starter

LE1D 3-Phase DOL Magnetic Motor Starter

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LE1D
Electricity Type:AC
Sold out
3VE1 DZ108 Manual Motor Protection Circuit Breaker

3VE1 DZ108 Manual Motor Protection Circuit Breaker

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:3VE1
Phase:3
Main Circuit Rating Current:0.1A ~ 20A
Type:Moulded Case
Sold out
3RV1 Manual Motor Starter Protector Circuit Breaker
3RV1 Manual Motor Starter Protector Circuit Breaker

3RV1 Manual Motor Starter Protector Circuit Breaker

Rated Frequency:50/60hz
Type:Motor Manual Starter
BCD Curve:C
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:3RV1
Poles Number:3
Breaking Capacity:10kA
QX4A Automatic Star Delta Reduced Voltage Motor Starter

QX4A Automatic Star Delta Reduced Voltage Motor Starter

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:QX4A
GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker
GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker

GV2ME GV2P GV3P Manual Motor Starter Circuit Breaker

Rated Frequency:50/60hz
Type:Motor Manual Starter
Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:GV2ME GV3ME GV2P GV3P
Poles Number:3
Breaking Capacity:16kA
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • NJX3 Miniature Relay for HVAC NJX3 Miniature Relay for HVAC
  • NJX2 General Purpose Relay NJX2 General Purpose Relay
  • NJX12 Miniature Relay NJX12 Miniature Relay
  • NJVA1 Voltage and Current Protector NJVA1 Voltage and Current Protector
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the star.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...