Chint NU6-III Surge Arrester Chint NU6-III Surge Arrester
  • Home
  • Products
    Chint NU6-III Surge Arrester

    Automation & Control

    Chint NU6-III Surge Arrester

    Circuit Breaker & Fuses

    Chint NU6-III Surge Arrester

    Din-Rail Mounted Products

    Chint NU6-III Surge Arrester

    Distribution Box & Cabinet

    Chint NU6-III Surge Arrester

    Load Center & Meter Bases

    Chint NU6-III Surge Arrester

    Solar PV Products

    Chint NU6-III Surge Arrester

    Electrical Accessories

    Chint NU6-III Surge Arrester

    Chint Electrical Materials

  • About
  • Blog
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint NU6-III Surge Arrester Chint NU6-III Surge Arrester
Search
Chint NU6-III Surge Arrester
Click to enlarge
Home Chint Electrical Materials Chint MCB Chint NU6-III Surge Arrester
Chint NXA ACB 3P 4P NXA16N NXA20N NXA32N NXA40N NXA63N NXA63H 1600A 2000A 2500A 3200A 4000A 6300A CHNT Chint Air Circuit Breaker
Chint NXA ACB 3P 4P NXA16N NXA20N NXA32N NXA40N NXA63N NXA63H 1600A 2000A 2500A 3200A 4000A 6300A CHNT Chint Air Circuit Breaker
Back to products
3Pole 6A 230V NO LC1K0610P7 LC1K06103P7 LC1K06105P7 LC1K06107P7 NC LC1K0601P7 LC1K06013P7 LC1K06015P7 LC1K06017P7 Contactor
3Pole 6A 230V NO LC1K0610P7 LC1K06103P7 LC1K06105P7 LC1K06107P7 NC LC1K0601P7 LC1K06013P7 LC1K06015P7 LC1K06017P7 Contactor

Chint NU6-III Surge Arrester

Type:T3
Brand Name:Chint
Place of Origin:China
Model Number:NU6-III
Rated Voltage:385V
Max Discharge current:10 A
SKU: 1600514733897 Category: Chint MCB

Where to Use NU6 SPD Surge Protector?

The Chint NU6-III Surge Arrester is a Surge Protective Device (SPD) designed to protect electrical systems from transient overvoltages caused by lightning strikes or switching surges. With discharge capacity up to 40kA, this SPD provides reliable protection for distribution boards, industrial equipment, communication systems, and sensitive electronics.

Why SPD Protection is Essential

  • Lightning Protection - Diverts lightning-induced surges safely to earth
  • Equipment Protection - Prevents damage to sensitive electronics, computers, and industrial controls
  • Fire Prevention - Reduces risk of electrical fires caused by overvoltage
  • Business Continuity - Minimizes downtime from surge-related equipment failures

Technical Specifications

ModelNU6
TypeType 2 (Class II/C)
Max Discharge Current (Imax)40kA
Voltage Protection Level (Up)≤1.5kV - ≤2.5kV (depending on model)
StandardIEC 61643-11 / GB 18802.1

SPD Type Selection Guide

TypeLocationProtection Level
Type 1 (Class I/B)Main distribution board, at service entranceProtection against direct lightning strikes
Type 2 (Class II/C)Sub-distribution boardsProtection against indirect strikes and switching surges
Type 3 (Class III/D)Near sensitive equipmentFine protection for electronics

FAQs

Q: Where should I install the SPD?

A: Install Type 1 SPD at the main incoming distribution board (near the main breaker). Type 2 SPD should be installed at sub-distribution boards or downstream panels. For sensitive equipment, add Type 3 protection near the device.

Q: Does SPD need replacement after a surge?

A: The NU6 has visual indication (green/red window) showing if protection is active. After major surges, the module may need replacement. Some models have replaceable cartridges for cost-effective maintenance.

  • Description
  • Additional information
Description

Chint original NU6-III Type 3 SPD Surge Arrester 10kV 5kA 275V 320V 385V T3 Class III Type D CHNT Type 3 Surge protection device

   

Chint NU6-Ⅲ Low-voltage Surge Arrester

 

1. General
1.1 Certificates: international certificates are under proceeding;
1.2 Electric ratings: Single phase power distribution and control system of AC50Hz, 230V;
1.3 Short circuit current: up to 5kA (8/20μs);
1.4 Application: Protect electric system and on-loading electrical apparatus from lightening and instantaneous over-voltage;
1.5 Standard:IEC61643-1, EN61643-11

Additional information
Weight 0.3 kg
Dimensions 22 × 22 × 22 cm
Number of Pole

2

Nominal Discharge current

5kA

Related products

Chint NB1-63DC DC MCB
Chint NB1-63DC DC MCB

Chint NB1-63DC DC MCB

BCD Curve:C
Type:MCB
Brand Name:Chint
Place of Origin:China
Model Number:NB1-63DC
Breaking Capacity:6kA
Rated Voltage:12 - 1000V DC
Type:Mini
Chint NXB-63 MCB
Chint NXB-63 MCB

Chint NXB-63 MCB

BCD Curve:B, C, D
Type:MCB
Brand Name:Chint
Place of Origin:China
Model Number:NXB-63
Rated Frequency (Hz):50/60Hz
Protection:LSI
Breaking Capacity:6kA
Rated Voltage:220-240V, 380-415V
Type:Mini
Chint DZ158-125 MCB

Chint DZ158-125 MCB

BCD Curve:C
Type:MCB
Brand Name:Chint
Place of Origin:China
Province:Zhejiang
Model Number:DZ158-125
Rated Frequency (Hz):50Hz, 60Hz
Protection:LSI
Breaking Capacity:6kA, 10kA
Rated Voltage:230/400V
Brand:Chint
Poles Number:1P/2P/3P/4P
Chint SHT-X3 Shunt Release

Chint SHT-X3 Shunt Release

Brand Name:Chint
Place of Origin:China
Model Number:SHT-X3
rated voltage:AC 230V 400V AC DC 24V 48V
Power:3A, 6A
Chint CB-125A MCB
Chint CB-125A MCB

Chint CB-125A MCB

The CHINT CB-125A Moulded Case Circuit Breaker (MCCB) offers reliable overload and short-circuit protection for AC circuits up to 415 V and
Chint OUVR-2 Over Voltage and Under Voltage Protector
Chint OUVR-2 Over Voltage and Under Voltage Protector

Chint OUVR-2 Over Voltage and Under Voltage Protector

Brand Name:Chint
Place of Origin:China
Model Number:OUVR-2
Chint NXB-125 MCB (80A-125A, AC/DC)
Chint NXB-125 MCB (80A-125A, AC/DC)

Chint NXB-125 MCB (80A-125A, AC/DC)

BCD Curve:B,C,D
Type:MCB
Brand Name:CHINT
Place of Origin:China
Model Number:NXB-125
Rated Frequency (Hz):50Hz,60Hz
Protection:LSI
Breaking Capacity:6kA,10kA
Rated Voltage:220V,230V,240V,380V,415V
Type:Mini
Sold out
Chint NX8 Consumer Unit
Chint NX8 Consumer Unit

Chint NX8 Consumer Unit

rated voltage:690V
Brand Name:Chint
Place of Origin:China
Model Number:NX8
Rated Current:150A
Color:White
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NXHB-125 MCB Chint NXHB-125 MCB
  • Chint NBH-100 MCB Chint NBH-100 MCB
  • Chint CB-125A MCB Chint CB-125A MCB
  • 33671 Replacement MN UVR Voltage release trip 200-250V Compact NS Circuit breaker or Switch disconnector MN undervoltage release 33671 Replacement MN UVR Voltage release trip 200-250V Compact NS Circuit breaker or Switch disconnector MN undervoltage release
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the cup.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...