Chint NRE8 Electronic Overload Relay Chint NRE8 Electronic Overload Relay
  • Home
  • Products
    Chint NRE8 Electronic Overload Relay

    Automation & Control

    Chint NRE8 Electronic Overload Relay

    Circuit Breaker & Fuses

    Chint NRE8 Electronic Overload Relay

    Din-Rail Mounted Products

    Chint NRE8 Electronic Overload Relay

    Distribution Box & Cabinet

    Chint NRE8 Electronic Overload Relay

    Load Center & Meter Bases

    Chint NRE8 Electronic Overload Relay

    Solar PV Products

    Chint NRE8 Electronic Overload Relay

    Electrical Accessories

    Chint NRE8 Electronic Overload Relay

    Chint Electrical Materials

  • About
  • Blog
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint NRE8 Electronic Overload Relay Chint NRE8 Electronic Overload Relay
Search
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay
Click to enlarge
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay
Chint NRE8 Electronic Overload Relay
Home Chint Electrical Materials Chint Contactor & Overload Relays Chint NRE8 Electronic Overload Relay
Breaker Panel Box 6 Space 125A Loadcenter 1 Phase Single Phase Main Lug Load Center
Breaker Panel Box 6 Space 125A Loadcenter 1 Phase Single Phase Main Lug Load Center
Back to products
Breaker Panel Box 4 Space 125A Loadcenter Single Phase Main Lug Load Center
Breaker Panel Box 4 Space 125A Loadcenter Single Phase Main Lug Load Center

Chint NRE8 Electronic Overload Relay

Brand Name:Chint
Theory:Thermal Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NRE8
Contact Load:High Power
Protect Feature:Sealed
SKU: 1769746268709462016 Category: Chint Contactor & Overload Relays

Where to Use NRE8 Electronic Overload Relay?

The Chint NRE8 Electronic Overload Relay is an advanced electronic overload relay providing precise motor protection with digital accuracy. Unlike thermal relays, the NRE8 uses current transformers and microprocessor technology for superior protection in critical applications such as HVAC systems, pumping stations, conveyor systems, and process automation.

Electronic vs Thermal Overload - Key Advantages

  • No Heating Required - Trips immediately on overload, no thermal lag time
  • Wide Current Range - Single unit covers 0.1A - 630A with dial adjustment
  • Earth Fault Protection - Detects ground faults in addition to overload/phase failure
  • Phase Imbalance Protection - Trips when current difference between phases exceeds set limit
  • Trip Memory - Records last trip cause for troubleshooting

FAQs

Q: When should I choose electronic over thermal overload?

A: Choose NRE8 for: critical motors where downtime is expensive, applications requiring earth fault protection, wide current adjustment range needs, or environments with temperature extremes where thermal relays may drift.

  • Description
Description

Chint NRE8 NRE8-25 NRE8-40 NRE8-100 NRE8-200 NRE8-630 25A 40A 100A 160A 200A 315A 400A 500A 630A CHNT Electronic Overload Relay

   

Chint NRE8 Electronic Overload Relay

 

General

    1 Certificates: CE, UKrSEPRO, UL;

    2 Electrical ratings: AC50/60Hz, 690V;

    3 Standards: IEC/EN 60947-4-1, UL508

 

Features
    1 Three-phase electronic type, tripping class10A;
    2 Energy saving up to 80% compared with bimetallic type;
    3 Phase-failure protection;
    4 Current setting continuously adjustable;
    5 Two indicator lights available for indicating normal, overload time-delay, phase-failure and phase-failure time-delay status respectively;
    6 Manual test mechanism;
    7 Manual reset button;
    8 A pair of N/C and N/O contacts;
    9 Two mounting versions: independent or combined with a contactor.

Related products

Sold out
Chint CJ19 Contactor for Capacitor Switching
Chint CJ19 Contactor for Capacitor Switching

Chint CJ19 Contactor for Capacitor Switching

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:CJ19
Phase:3
Main Circuit Rating Current:25A - 275A
Chint NXR Thermal Overload Relay
Chint NXR Thermal Overload Relay

Chint NXR Thermal Overload Relay

Brand Name:Chint
Theory:Thermal Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NXR
Contact Load:High Power
Protect Feature:Sealed
Chint NC2 Contactor
Chint NC2 Contactor

Chint NC2 Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NC2
Phase:3
Main Circuit Rating Current:630A,400A,115A,150A,185A,225A,265A,330A,500A,800A
Sold out
Chint CJX1-K Vacuum Contactor
Chint CJX1-K Vacuum Contactor

Chint CJX1-K Vacuum Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:CJX1-K
Phase:3
Main Circuit Rating Current:225A ~ 800A
Chint NKB1 Control & Protective Switching Device
Chint NKB1 Control & Protective Switching Device

Chint NKB1 Control & Protective Switching Device

Brand Name:Chint
Place of Origin:China
Model Number:NKB1
Certification:CCC, CE
Sold out
Chint NCK3 Definite Purpose Contactor
Chint NCK3 Definite Purpose Contactor

Chint NCK3 Definite Purpose Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NCK3
Phase:3
Main Circuit Rating Current:20A-40A
Sold out
Chint CJ40 Contactor
Chint CJ40 Contactor

Chint CJ40 Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:CJ40
Phase:3
Main Circuit Rating Current:63A - 1000A
Sold out
Chint NCK5 Definite Purpose Contactor
Chint NCK5 Definite Purpose Contactor

Chint NCK5 Definite Purpose Contactor

Electricity Type:AC
Brand Name:Chint
Place of Origin:China
Model Number:NCK5
Phase:1
Main Circuit Rating Current:20A ~ 40A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NXHB-125 MCB Chint NXHB-125 MCB
  • Chint NBH-100 MCB Chint NBH-100 MCB
  • Chint CB-125A MCB Chint CB-125A MCB
  • 33671 Replacement MN UVR Voltage release trip 200-250V Compact NS Circuit breaker or Switch disconnector MN undervoltage release 33671 Replacement MN UVR Voltage release trip 200-250V Compact NS Circuit breaker or Switch disconnector MN undervoltage release
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the cup.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...