Chint NB2LE 18mm RCBO (SAA Certified) Chint NB2LE 18mm RCBO (SAA Certified)
  • Home
  • Products
    Chint NB2LE 18mm RCBO (SAA Certified)

    Automation & Control

    Chint NB2LE 18mm RCBO (SAA Certified)

    Circuit Breaker & Fuses

    Chint NB2LE 18mm RCBO (SAA Certified)

    Din-Rail Mounted Products

    Chint NB2LE 18mm RCBO (SAA Certified)

    Distribution Box & Cabinet

    Chint NB2LE 18mm RCBO (SAA Certified)

    Load Center & Meter Bases

    Chint NB2LE 18mm RCBO (SAA Certified)

    Solar PV Products

    Chint NB2LE 18mm RCBO (SAA Certified)

    Electrical Accessories

    Chint NB2LE 18mm RCBO (SAA Certified)

    Chint Electrical Materials

  • About
  • Blog
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint NB2LE 18mm RCBO (SAA Certified) Chint NB2LE 18mm RCBO (SAA Certified)
Search
Sold out
Chint NB2LE 18mm RCBO (SAA Certified)
Chint NB2LE 18mm RCBO (SAA Certified)
Click to enlarge
Chint NB2LE 18mm RCBO (SAA Certified)
Chint NB2LE 18mm RCBO (SAA Certified)
Home Chint Electrical Materials Chint RCCB RCBO Chint NB2LE 18mm RCBO (SAA Certified)
Albright Equivalent SW80 SW82 100A 125A 12V 24V 1NO Normal Open SPST Solenoid switch Electric Vehicle DC Contactor
Albright Equivalent SW80 SW82 100A 125A 12V 24V 1NO Normal Open SPST Solenoid switch Electric Vehicle DC Contactor
Back to products
Chint original NXB-40 DPN 6A 10A 16A 20A 25A 32A 40A Chnt 1P+N Mini Circuit Breaker
Chint original NXB-40 DPN 6A 10A 16A 20A 25A 32A 40A Chnt 1P+N Mini Circuit Breaker

Chint NB2LE 18mm RCBO (SAA Certified)

Rated Frequency:50/60hz
Type:Residual Current
BCD Curve:C
Brand Name:Chint
Place of Origin:China
Model Number:NB2LE
Breaking Capacity:6kA
Width:Single Module 18mm
Breacking Capacity:6kA
Poles Number:Twin
SKU: 10000007599642 Category: Chint RCCB RCBO

Where to Use NB2LE?

The Chint NB2LE 18mm RCBO (SAA Certified) is a Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed for leakage protection and personal safety in residential electrical panels, commercial buildings, wet locations (bathrooms, kitchens), outdoor power supplies, and anywhere personal protection is critical. This RCBO combines residual current protection (leakage detection) with overcurrent protection (overload/short-circuit) in a single device, saving space in distribution boards while providing comprehensive circuit protection. The single-module (18mm) design makes it ideal for space-constrained panels where standard width devices won't fit.

Why Choose NB2LE Series?

  • Personal Safety Protection - Detects dangerous leakage currents before they cause electric shock
  • Type AC (pure AC) - Standard AC detection (cost-effective for basic residential applications)
  • High Sensitivity Options - 30mA / 100mA / 300mA trip settings for different protection levels
  • Fast Response Time - Trips within 30ms when leakage is detected, well below dangerous exposure times
  • Dual Protection in One - RCBO combines RCD + MCB functions, reducing panel space by 50%
  • Ultra-Compact Design - Single 18mm module width saves valuable DIN rail space
  • IEC 61008/61009 Certified - Complies with international residual current device standards
  • Chint Original Quality - CE, SAA, CCC approved with 2-year warranty

Sensitivity (Trip Current) Selection Guide

Choose the right sensitivity level for your application:

Sensitivity Application Typical Use
10mA / 30mA Personal Protection Bathrooms, kitchens, outdoor sockets, medical locations - where human contact risk is highest
100mA Fire Protection / Indirect Contact General distribution circuits, sub-panels, areas with indirect contact risk
300mA Equipment / Fire Protection Main incoming protection, large installations, industrial equipment protection

Type AC vs Type A vs Type B - Which One?

Type Detects When to Use
Type AC Pure AC only Basic residential with standard resistive loads (heaters, incandescent lights). Most economical.
Type A (Recommended) AC + Pulsating DC Modern homes with electronic loads: washing machines, LED drivers, variable speed tools, computers. Recommended for new installations.
Type B AC + All DC (incl. smooth) Solar PV systems, EV charging, VFDs, medical equipment, DC-powered installations. Required for DC applications.

Technical Specifications

Parameter Specification
Model Series NB2LE
Device Type RCBO (RCD + MCB)
Rated Current 6A - 125A
Pole Configuration 2P / 4P
Residual Sensitivity 30mA / 100mA / 300mA
Detection Type Type AC (pure AC)
Trip Time ≤30ms at rated residual current
Standard IEC 61008 (RCCB) / IEC 61009 (RCBO)

Frequently Asked Questions

Q: What is the difference between RCCB and RCBO?

A: RCCB (Residual Current Circuit Breaker) provides only leakage protection - it detects earth faults and disconnects power but doesn't protect against overloads or short circuits. RCBO (Residual Current Breaker with Overcurrent protection) combines RCD + MCB in one device - it protects against leakage AND overcurrent/overload/short-circuit. RCBO saves space in distribution boards and provides complete protection.

Q: 30mA vs 300mA - which sensitivity should I choose?

A: 30mA (or 10mA) is required for personal protection in locations with high shock risk (bathrooms, kitchens, outdoor power, medical facilities). This level protects humans from fatal electric shock. 300mA is used for equipment and fire protection on main incoming circuits - it prevents fires from insulation faults but won't protect against direct contact. Never use 300mA for socket outlet circuits where people may touch appliances.

Q: Do I need Type A or is Type AC sufficient?

A: For new installations, always choose Type A. Modern appliances (washing machines, LED lights, computers, variable speed tools) generate pulsating DC leakage currents that Type AC cannot detect. Type A provides better safety and is now required by updated electrical codes in many countries. Type AC is only suitable for basic installations with purely resistive loads (heaters, incandescent bulbs) and should be considered legacy technology.

Need Help Selecting RCCB/RCBO? Our electrical engineers can advise on the right sensitivity, type, and rating for your installation. Contact us at sales@sntelec.com or WhatsApp +86-18019187010.

  • Description
  • Additional information
Description

Chint NB2LE Single module 1P+N 18mm 6kA CE Semko SAA certified 6A 10A 16A 20A 25A 32A 40A Type A or AC CHNT RCBO Circuit Beaker

 

Chint NB2LE residual current operated circuit breakers (RCBO) are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be protected. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

   

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Rated Current

25A, 20A, 10A, 16A, 32A, 6A, 40A

Rated Voltage

240V

Related products

Sold out
Chint NBH8LE-40 RCBO

Chint NBH8LE-40 RCBO

Rated Frequency:50/60hz
Type:Residual Current
Brand Name:Chint
Place of Origin:China
Model Number:NBH8LE-40
Breaking Capacity:6kA
Poles Number:Twin
Sold out
Chint NXBLE-32 RCBO
Chint NXBLE-32 RCBO

Chint NXBLE-32 RCBO

Rated Frequency:50/60hz
Type:Residual Current
BCD Curve:C
Brand Name:Chint
Place of Origin:China
Model Number:NXBLE-32, NXBLE-63
Breaking Capacity:6kA,10kA
Poles Number:Twin
Chint NL1-63 RCCB (Type AC, Type A)
Chint NL1-63 RCCB (Type AC, Type A)

Chint NL1-63 RCCB (Type AC, Type A)

BCD Curve:Other
Type:RCCB
Brand Name:CHINT
Place of Origin:China
Model Number:NL1-63
Breaking Capacity:6kA
Rated Voltage:230/400V, 240/415V
Sold out
Chint NXBLE-63 RCBO
Chint NXBLE-63 RCBO

Chint NXBLE-63 RCBO

Rated Frequency:50/60hz
Type:Residual Current
Brand Name:Chint
Place of Origin:China
Model Number:NXBLE-63
Poles Number:1P+N, 2P, 3P, 3P+N, 4P
Breaking Capacity:6kA
Sold out
Chint NB1L-40 RCBO
Chint NB1L-40 RCBO

Chint NB1L-40 RCBO

Rated Frequency:50/60hz
Type:RCbO
BCD Curve:C
Brand Name:CHINT
Place of Origin:China
Model Number:NB1L-40, NB1L-40H
Poles Number:2, 4
Breaking Capacity:10kA,6kA
Product name:NB1L-40, NB1L-40H
Rated breaking capacity:6kA, 10kA
Pole Number:1P+N 2P 3P 3P+N 4P
Manufactuer:Chint electric
Rated current:1A - 40A
Action type:Type AC or Type A
Sold out
Chint DZ158LE-125 RCBO
Chint DZ158LE-125 RCBO

Chint DZ158LE-125 RCBO

Rated Frequency:50/60hz
Type:Residual Current
Brand Name:Chint
Place of Origin:China
Model Number:DZ158LE-125
Poles Number:1234
Breaking Capacity:6kA
Sold out
Chint NXBLE-40 RCBO

Chint NXBLE-40 RCBO

Rated Frequency:50/60hz
Type:Residual Current
Brand Name:Chint
Place of Origin:China
Model Number:NXBLE-40
Breaking Capacity:6kA
Poles Number:Twin
Chint NXBLE-63Y RCBO
Chint NXBLE-63Y RCBO

Chint NXBLE-63Y RCBO

Rated Frequency:50/60hz
Type:Residual Current
Brand Name:Chint
Place of Origin:China
Model Number:NXBLE-63Y
Breaking Capacity:6kA
Poles Number:Twin
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NXHB-125 MCB Chint NXHB-125 MCB
  • Chint NBH-100 MCB Chint NBH-100 MCB
  • Chint CB-125A MCB Chint CB-125A MCB
  • 33671 Replacement MN UVR Voltage release trip 200-250V Compact NS Circuit breaker or Switch disconnector MN undervoltage release 33671 Replacement MN UVR Voltage release trip 200-250V Compact NS Circuit breaker or Switch disconnector MN undervoltage release
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the truck.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...