CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
  • Home
  • Products
    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Automation & Control

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Circuit Breaker & Fuses

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Din-Rail Mounted Products

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Distribution Box & Cabinet

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Load Center & Meter Bases

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Solar PV Products

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Electrical Accessories

    CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

    Chint Electrical Materials

  • About
  • Blog
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
Search
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
Click to enlarge
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
Home Electrical Accessories Others CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec
CHINT NA1-3200X-2500M/3200M 3P Intelligent Universal ACB
CHINT NA1-3200X-2500M/3200M 3P Intelligent Universal ACB
Back to products
CHINT NM1-250S to NM1-630S 3P/4P Moulded Case Breaker
CHINT NM1-250S to NM1-630S 3P/4P Moulded Case Breaker

CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec

BCD Curve:Other
Type:RCCB
Brand Name:Chint
Place of Origin:China
Model Number:NL1-63
Rated Frequency (Hz):50Hz
Breaking Capacity:6kA
Rated Voltage:230/400V, 240/415V
SKU: 1770400757380554752 Category: Others

Where to Use NL1?

The CHINT NL1-63 2P/4P RCCB RCD Earth Leakage Switch Type A/AC| SNT Elec is a Residual Current Circuit Breaker (RCCB/RCD) designed for leakage protection and personal safety in residential electrical panels, commercial buildings, wet locations (bathrooms, kitchens), outdoor power supplies, and anywhere personal protection is critical. This RCCB provides dedicated leakage current detection with high sensitivity (30mA / 100mA / 300mA), automatically disconnecting power when dangerous leakage currents are detected, preventing electric shock hazards.

Why Choose NL1 Series?

  • Personal Safety Protection - Detects dangerous leakage currents before they cause electric shock
  • Type A (pulsating DC capable) - Detects both AC and pulsating DC residual currents (modern appliances, LED drivers)
  • High Sensitivity Options - 30mA / 100mA / 300mA trip settings for different protection levels
  • Fast Response Time - Trips within 30ms when leakage is detected, well below dangerous exposure times
  • IEC 61008/61009 Certified - Complies with international residual current device standards
  • Chint Original Quality - CE, SAA, CCC approved with 2-year warranty

Sensitivity (Trip Current) Selection Guide

Choose the right sensitivity level for your application:

Sensitivity Application Typical Use
10mA / 30mA Personal Protection Bathrooms, kitchens, outdoor sockets, medical locations - where human contact risk is highest
100mA Fire Protection / Indirect Contact General distribution circuits, sub-panels, areas with indirect contact risk
300mA Equipment / Fire Protection Main incoming protection, large installations, industrial equipment protection

Type AC vs Type A vs Type B - Which One?

Type Detects When to Use
Type AC Pure AC only Basic residential with standard resistive loads (heaters, incandescent lights). Most economical.
Type A (Recommended) AC + Pulsating DC Modern homes with electronic loads: washing machines, LED drivers, variable speed tools, computers. Recommended for new installations.
Type B AC + All DC (incl. smooth) Solar PV systems, EV charging, VFDs, medical equipment, DC-powered installations. Required for DC applications.

Technical Specifications

Parameter Specification
Model Series NL1
Device Type RCCB/RCD (Pure Leakage Protection)
Rated Current 6A - 125A
Pole Configuration 2P / 4P
Residual Sensitivity 30mA / 100mA / 300mA
Detection Type Type A (pulsating DC capable)
Trip Time ≤30ms at rated residual current
Standard IEC 61008 (RCCB) / IEC 61009 (RCBO)

Frequently Asked Questions

Q: What is the difference between RCCB and RCBO?

A: RCCB (Residual Current Circuit Breaker) provides only leakage protection - it detects earth faults and disconnects power but doesn't protect against overloads or short circuits. RCBO (Residual Current Breaker with Overcurrent protection) combines RCD + MCB in one device - it protects against leakage AND overcurrent/overload/short-circuit. RCBO saves space in distribution boards and provides complete protection.

Q: 30mA vs 300mA - which sensitivity should I choose?

A: 30mA (or 10mA) is required for personal protection in locations with high shock risk (bathrooms, kitchens, outdoor power, medical facilities). This level protects humans from fatal electric shock. 300mA is used for equipment and fire protection on main incoming circuits - it prevents fires from insulation faults but won't protect against direct contact. Never use 300mA for socket outlet circuits where people may touch appliances.

Q: Do I need Type A or is Type AC sufficient?

A: For new installations, always choose Type A. Modern appliances (washing machines, LED lights, computers, variable speed tools) generate pulsating DC leakage currents that Type AC cannot detect. Type A provides better safety and is now required by updated electrical codes in many countries. Type AC is only suitable for basic installations with purely resistive loads (heaters, incandescent bulbs) and should be considered legacy technology.

Need Help Selecting RCCB/RCBO? Our electrical engineers can advise on the right sensitivity, type, and rating for your installation. Contact us at sales@sntelec.com or WhatsApp +86-18019187010.

  • Description
  • Additional information
Description

Chint original NL1-63 RCD, 2P / 4P, Type A / Type AC

   

1. General 

1.1 Function

      Control electric circuits.

      Protect people against indirect contacts and additional protection against direct contacts.

      Protect installations against fire hazard due to insulation faults.

      Residual current circuit breakers are used in housing, tertiary sector and industry.

 

1.2 Selection

      Detectable wave form

      AC class

      Tripping is ensured for slowly increasing sinusoidal AC residual currents.

      A class

      Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

      – S, G/SI class

      Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied  suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With       the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

 

      Tripping sensitivity

      10mA – precision instrument leakage protection and bathroom use.

      30mA – additional protection against direct contact.

      100mA – coordinated with the earth system according to the formula IΔn <50/R, to provide protection against indirect contacts;       

      300mA/500mA – protection against indirect contacts, as well as fire hazard.

 

      Tripping time

      Instantaneous – It ensures instantaneous tripping (without time-delay).

      Short time delay – It ensures any tripping at least 10ms.

      Selective – It ensures total discrimination with a nonselective RCD placed downstream.

 

 

 
Additional information
Weight 0.3 kg
Dimensions 30 × 30 × 30 cm

Related products

LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor
LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor

LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:9A
1P-4P 250V-1000V Solar PV System DC Mini Circuit Breaker
1P-4P 250V-1000V Solar PV System DC Mini Circuit Breaker

1P-4P 250V-1000V Solar PV System DC Mini Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DZ47-63Z
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:6kA
Rated Voltage:500V,1000V,250V
LC1D 3P/4P AC DC Magnetic Contactor 9A-95A 12V-220V Coil
LC1D 3P/4P AC DC Magnetic Contactor 9A-95A 12V-220V Coil

LC1D 3P/4P AC DC Magnetic Contactor 9A-95A 12V-220V Coil

Electricity Type:AC/DC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:9A 12A 18A 25A 30A 32A 40A 50A 65A 80A 95A
LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor
LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor

LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K09
Phase:3
Main Circuit Rating Current:9A
THQL2170 2-Pole 70A 120V/240V 10kA Q-Line Circuit Breaker
THQL2170 2-Pole 70A 120V/240V 10kA Q-Line Circuit Breaker

THQL2170 2-Pole 70A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:100V,220V,230V,240V
LC1D12 3P 12A AC Contactor 24V-240V Coil Options
LC1D12 3P 12A AC Contactor 24V-240V Coil Options

LC1D12 3P 12A AC Contactor 24V-240V Coil Options

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:12A
LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A
LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A

LC1K 220Vac/230Vac Mini AC Contactor 6A/9A/12A/16A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
750V-1000V High Voltage Automotive EV Contactor 50A-400A
750V-1000V High Voltage Automotive EV Contactor 50A-400A

750V-1000V High Voltage Automotive EV Contactor 50A-400A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • CHINT YBLX-P1 Travel Switch CHINT YBLX-P1 Travel Switch
  • CHINT YBLX-ME Travel Switch CHINT YBLX-ME Travel Switch
  • CHINT YBLX-K3 Travel Switch CHINT YBLX-K3 Travel Switch
  • CHINT YBLX-K1 Travel Switch CHINT YBLX-K1 Travel Switch
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the cup.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...